Ricardo
| MODEL OF GEN-SET | GB15SR | GB20SR | GB24SR | GB30SR | |
| Continuous output of gen-set | 15KW | 20KW | 24KW | 30KW | |
| DIESEL ENGINE | Model | R495D | R3105D | R3105ZD | R4105D |
| Type | Water-cooled, Four-stroke, in-line, direct injection | ||||
| No.of cyliner | 4 | 4 | 4 | 4 | |
| Bore*Stroke (mm) | 95*115 | 100*115 | 100*115 | 105*110 | |
| Ttl.Displacement(L) | 3.26 | 3.61 | 3.61 | 3.81 | |
| Compressionratio | 16.5:1 | 17.5:1 | 17.5:1 | 19.5:1 | |
| Induction system | natural | natural | |||
| Ratedoutput(KW) | 26KW | 30.1KW | 30.1KW | 36.4KW | |
| Ratedspeed (rpm) | 1500 | ||||
| Fuelconsumption(g/kw.h) | ≤251.6 | ≤251.6 | ≤251.6 | ≤251.6 | |
| Oil consumption (g/kw.h) | 1.38 | 1.4 | 1.4 | 1.4 | |
| Cooling method | water-cooled with radiator | ||||
| Starting method | D.C.12V or 24V Electric starting | ||||
| ALTERNATOR | Model(stamfordas option) | TF(D)W-15KW | TF(D)W-20KW | TF(D)W-24KW | TF(D)W-30KW |
| Rated power | 15KW | 20KW | 25KW | 30KW | |
| Rated voltage | 380/220, 400/230, 220V, 230V etc. | ||||
| Rated current | According to the selected voltage and phase | ||||
| Rated frequency | 50HZ | ||||
| Ratedspeed(rpm) | 1500 | ||||
| Power factor | 1 for single phase/0.8 lagging for 3-phase | ||||
| Phase connection | 1-phase or 3-phase | ||||
| Winding connection | 3 or 4 -wire connected(12-wire for 3-phase) | ||||
| Excitation method | Brushless | ||||
| 15GF(LDE)Voltage regulation | AVR | ||||
| CONTROL PANEL | V-meter, A-meter, Frequency meter, circuit breaker, transfer switch, AVR, temp.and pressure gauges, indicating lamp, hour meter,engine protection device, key starter, etc. | ||||
| G/N. WET (kg) | 960/900 | 980/920 | 1000/940 | 1100/1000 | |
| PACKING SIZE (m) | 2*0.96*1.1 | 2*0.96*1.1 | 2*0.96*1.1 | 2.3*1.1*1.3 | |
| MODEL OF GEN-SET | GB15SR | GB20SR | GB24SR | GB30SR | |
| Continuous output of gen-set | 15KW | 20KW | 24KW | 30KW | |
| DIESEL ENGINE | Model | R495D | R3105D | R3105ZD | R4105D |
| Type | Water-cooled, Four-stroke, in-line, direct injection | ||||
| No.of cyliner | 4 | 4 | 4 | 4 | |
| Bore*Stroke (mm) | 95*115 | 100*115 | 100*115 | 105*110 | |
| Ttl.Displacement(L) | 3.26 | 3.61 | 3.61 | 3.81 | |
| Compressionratio | 16.5:1 | 17.5:1 | 17.5:1 | 19.5:1 | |
| Induction system | natural | natural | |||
| Ratedoutput(KW) | 26KW | 30.1KW | 30.1KW | 36.4KW | |
| Ratedspeed (rpm) | 1500 | ||||
| Fuelconsumption(g/kw.h) | ≤251.6 | ≤251.6 | ≤251.6 | ≤251.6 | |
| Oil consumption (g/kw.h) | 1.38 | 1.4 | 1.4 | 1.4 | |
| Cooling method | water-cooled with radiator | ||||
| Starting method | D.C.12V or 24V Electric starting | ||||
| ALTERNATOR | Model(stamfordas option) | TF(D)W-15KW | TF(D)W-20KW | TF(D)W-24KW | TF(D)W-30KW |
| Rated power | 15KW | 20KW | 25KW | 30KW | |
| Rated voltage | 380/220, 400/230, 220V, 230V etc. | ||||
| Rated current | According to the selected voltage and phase | ||||
| Rated frequency | 50HZ | ||||
| Ratedspeed(rpm) | 1500 | ||||
| Power factor | 1 for single phase/0.8 lagging for 3-phase | ||||
| Phase connection | 1-phase or 3-phase | ||||
| Winding connection | 3 or 4 -wire connected(12-wire for 3-phase) | ||||
| Excitation method | Brushless | ||||
| 15GF(LDE)Voltage regulation | AVR | ||||
| CONTROL PANEL | V-meter, A-meter, Frequency meter, circuit breaker, transfer switch, AVR, temp.and pressure gauges, indicating lamp, hour meter,engine protection device, key starter, etc. | ||||
| G/N. WET (kg) | 960/900 | 980/920 | 1000/940 | 1100/1000 | |
| PACKING SIZE (m) | 2*0.96*1.1 | 2*0.96*1.1 | 2*0.96*1.1 | 2.3*1.1*1.3 | |